Rheem HB Duct Ready Series (touchscreen) error codes

Covers: Residential HB Duct Ready Series hybrid (touchscreen EcoNet display), Use & Care AP18095

Every code listed in Rheem's own manual for this series, with what it means and what Rheem says to do. Last checked 2026-10-03.

Is this your model? For the older hybrid with a color touchscreen (Settings, Status, Service and Mode buttons). Its manual is titled "Residential - HB Duct Ready Series" (AP18095-2, 1/18). To read alarms, press the blinking Service button, then the blinking alarms button.

CodeLabelWhat the manual says it means
A004Compressor Shutdown: Discharge-Suction Trip.Heating source defaults to elements due to compressor malfunction.
T005Compressor Shutdown: Discharge Temp High.Heating source defaults to elements due to compressor malfunction.
A006Suction Temperature Too Low.Heating source defaults to elements due to low air flow.
T007Compressor Shutdown: Comp.Feedback FailureHeating source defaults to elements due to compressor malfunction.
A007Compressor Shutdown: Comp.Feedback Failure.Heating source defaults to elements due to compressor malfunction.
A008Detected Dry Fire Condition.Dry Fire Protection-- Not sufficient water in the storage tank. Heater disabled.
T009Compressor wiring may be faulty.Heating source defaults to elements due to compressor malfunction.
A101Suction Temperature Sensor Failure.Heating source defaults to elements due to heat pump temperature sensor malfunction.
A102Ambient Temperature Sensor Failure.Heating source defaults to elements due to heat pump temperature sensor malfunction.
A103Lower Heater Temp Sensor Failure.Lower Tank Temperature Sensor malfunction. Heater disabled.
A104Upper Heater Temp Sensor Failure.Upper Tank Temperature Sensor malfunction. Heater disabled.
A105Evaporator Temp Sensor Failure.Heating source defaults to elements due to heat pump temperature sensor malfunction.
A106Discharge Temp Sensor Failure.Heating source defaults to elements due to heat pump temperature sensor malfunction.
A107Water Detected on Floor: Check for Leaks.Water is detected in the drain pan.
A108Condensate Blocked: Unclog Line.Heating source defaults to elements due to condensate drain blockage.
A125Lower Element Error or Relay Stuck Closed.Heating element or Control board failure. Heater disabled.
A126Upper Element Error or Relay Stuck Closed.Heating element or Control board failure. Heater disabled.
A127Element Wire Routing Error .Elements mis-wired or control board failure. Heater disabled.
A128Lower Element Relay Failure to Close Error.Control board relay failure. Heater Disabled.
A129Upper Element Relay Failure to Close Error.Control board relay failure. Heater Disabled.
A130Unit Off/Air Temp Freezing: Enable Unit.Ambient temperature below freezing. --FREEZE WARNING
T131Clean Filter ReminderAir filter routine maintenance reminder.
T132Water Heater difficulty satisfying demand.Water Heater cannot satisfy demand.
A200High Water Temp! [ECO].ECO Tripped. Heater disabled.
T300Water Leak Sensor Not Installed.Water Leak Sensor Not Installed.
A900Controller Fault.Controller Malfuntion. Heater disabled. [sic]
T901Controller Fault.Controller Malfuntion. Heater disabled. [sic]
A902Controller Fault.Controller Malfuntion. Heater disabled. [sic]
A903Controller Fault.Controller Malfuntion. Heater disabled. [sic]
A904Controller Fault.Controller Malfuntion. Heater disabled. [sic]
A905Controller Fault.Controller Malfuntion. Heater disabled. [sic]

Rheem's manual for this series does not list error codes; see the troubleshooting section below.