A. O. Smith · Voltex 120V plug-in (HPTV, HPV10)
A. O. Smith Voltex 120V plug-in (HPTV, HPV10) error code 081
Condensate management
What it means
Condensate management. NOTICE: The Control Assembly will go into Limp Mode 3 until the failure is corrected.
How it shows: with an alert icon flashing (also flashing red LED and beeper)
What A. O. Smith says to do
1. Ensure unit is installed level. 2. Check for blocked condensate drain line, clear drain line as necessary. 3. If an accessory condensate pump was installed: Disconnect power to water heater and check control wire connections to condensate pump. Reconnect power to water heater. 4. Check to see if the accessory condensate pump is plugged in and has power. 5. Ensure the pump is operating properly, check pump outlet tube for blockage. 6. Repair or replace accessory condensate pump as necessary. 7. If problem persists, call our Technical Assistance Hotline which is listed on the water heater's warranty sheet.
The manual adds: "These instructions are brief and intended as guidance for a qualified person. If you lack the necessary skills to perform these procedures call the Technical Assistance Hotline which is listed on the water heater's warranty sheet for assistance." (Hybrid Electric Heat Pump Water Heater Installation Instructions and Use & Care Guide (120V), 100379653_2000812406, page 27)
Last checked 2026-10-03.
Safety first
- WARNING! Working near an energized circuit can result in severe injury or death from electrical shock. (p.28)
- WARNING! When you are finished, be sure all covers are secured to reduce the risk of fire and electric shock. (p.28)
From the manufacturer's manual for this series.
The same code on other models
Codes mean different things on different heaters. Match the series to the model number on your rating label.
- A. O. Smith Voltex AL Smart / Signature 900 Standard (HPTS, HPS10): 081
- A. O. Smith Voltex MAX / Signature 900 Premium (HPTA, HPA10): 081
Other Voltex 120V plug-in (HPTV, HPV10) codes
- 001 (Dry-fire)
- 003 (Upper thermistor sensor failure)
- 004 (Lower thermistor sensor failure)
- 006 (Internal Processor Error)
- 009 (Power supply voltage too low)
- 021 (Upper element circuit failure)
- 022 (Lower element circuit failure)
- 025 (Heat pump coil temperature sensor)
- 026 (Heat pump suction temperature sensor)
- 027 (Heat pump discharge temperature sensor)
- 028 (Ambient temperature sensor failure)
- 029 (Outlet temperature sensor failure)
- 031 (Water leak)
- 044 (SAC anode depleted)
- 046 (Shut-off valve)
- 047 (Smart Valve failure)
- 048 (Battery low energy)
- 080 (Air filter dirty)
- 083 (Compressor suction pressure too low)
- 084 (Compressor not functioning)
- 085 (Compressor discharge temperature too high)
- 086 (Fan speed feedback)
- HPO (Heat pump out of operating range)
- ICE (Heat pump defrost)
- CLR (Error code cleared)