Hybrid Heater Codes

Rheem heat pump water heater

Rheem ProTerra / Performance Platinum hybrid (Gen V, 240V) error codes

Covers: Hybrid Electric Heat Pump, 240V 'Gen V' platform: ProTerra (Performance Platinum XE..T10H.., Professional Prestige PROPH.. T2 ..) and earlier editions of the same Use & Care manual

Every code listed in Rheem's own manual for this series, with what it means and what Rheem says to do. Last checked 2026-10-03.

Is this your model? Rheem's product pages link this manual for ProTerra and Performance Platinum hybrids such as XE40T10H45U0, XE50T10H45U0/U1, XE50T10H22U1, XE80T10HS45U1 and Professional Prestige PROPH40/50/80 T2 RH375/RH400 models. The control has a text LCD with MODE, NEXT, UP, DOWN, ON-OFF, CLEAR ALARM, WiFi and ENTER buttons. To read an alarm, press NEXT until "Current Alarm" shows, then press the DOWN arrow.

CodeLabelWhat the manual says it means
A004Comp.Shutdown: Discharge-Suction TripHeating source defaults to elements due to compressor malfunction
A005Compressor Shutdown: Discharge Temp HighHeating source defaults to elements due to compressor malfunction
T005Compressor Shutdown: Discharge Temp HighHeating source defaults to elements due to low airflow
A006Suction Temperature Too LowHeating source defaults to elements due to compressor malfunction
T006Suction Temperature Too LowHeating source defaults to elements due to compressor malfunction
A008Detected Dry Fire ConditionDry fire protection- Not sufficient water in storage tank: Heater disabled
T009Compressor wiring may be faultyHeating source default to elements due to compressor malfunction
A009Compressor wiring may be faultyHeating source default to elements due to compressor malfunction
A101Suction Temperature Sensor FailureHeating source defaults to elements due to heat pump temperature sensor malfunction
A102Ambient Temperature Sensor FailureHeating source defaults to elements due to heat pump temperature sensor malfunction
A103Lower Heater Temp Sensor FailureLower tank temperature sensor malfunction. Heater disabled.
A104Upper Heater Temp Sensor FailureLower tank temperature sensor malfunction. Heater disabled.
A105Evaporator Temp Sensor FailureHeating source defaults to elements due to heat pump temperature malfunction.
A106Discharge Temp Sensor FailureHeating source defaults to elements due to heat pump temperature malfunction.
A107Water Detected on Floor: Check For LeaksWater is detected in the drain pan
A108Condensate Blocked: Unclog LineHeating source defaults to elements due to condensate drain blockage
A125Lower Element Error or Relay Stuck ClosedHeating element or control board failure. Heater disabled.
A126Upper Element Error or Relay Stuck ClosedHeating element or control board failure. Heater disabled.
A127Element Wire Routing ErrorElements mis-wired or control board failure. Heater disabled.
A128Lower Element Relay Failure to Close ErrorControl board relay failure. Heater disabled.
A129Upper Element Relay Failure to Close ErrorControl board relay failure. Heater disabled.
A130Unit Off/Air Temp Freezing: Enable UnitAmbient temperature is below freezing. --FREEZE WARNING
T131Clean Filter ReminderAir filter routine maintenance reminder
T132Water Heater difficulty satisfying demandWater heater can not satisfy demand
A120Shutoff Valve Can't Close ErrorShut-Off Valve malfunction
A121Shutoff Valve Can't Open ErrorShut-Off Valve malfunction
A122Shutoff Valve Inputs in ErrorShut-Off Valve malfunction
A123Shut-Off Valve Not InstalledShut-Off Valve malfunction
A200High Water Temp! [ECO] Call Tech ServiceECO Tripped. Heater Disabled
T300Water Leak Sensor Not InstalledWater Leak Sensor Not Installed
A502Time Clock needs to be programmedController malfunction. Heater disabled.
A503Time Clock not advancing time properlyController malfunction. Heater disabled.
T504WiFi Chip Communication ErrorController malfunction. Heater disabled.
A900Controller Fault: Call Tech ServiceController malfunction. Heater disabled.
T901Controller Fault: Call Tech ServiceController malfunction. Heater disabled.
A902Controller Fault: Call Tech ServiceController malfunction. Heater disabled.
A903Controller Fault: Call Tech ServiceController malfunction. Heater disabled.
A904Controller Fault: Call Tech ServiceController malfunction. Heater disabled.
A905Controller Fault: Call Tech ServiceController malfunction. Heater disabled.
A906Power Board Temp. Protection Sensor FailureController getting too hot.

Rheem's manual for this series does not list error codes; see the troubleshooting section below.

Safety first

From the manufacturer's manual for this series.

Troubleshooting without a code

Owner maintenance

Sources