Hybrid Heater Codes

Rheem · ProTerra / Performance Platinum hybrid (Gen V, 240V)

Rheem ProTerra / Performance Platinum hybrid (Gen V, 240V) error code A008

Detected Dry Fire Condition

What it means

Dry fire protection- Not sufficient water in storage tank: Heater disabled

Source: Electric Residential Hybrid Water Heater Use & Care Manual With Installation Instructions for the Installer, AP23657 Rev 04, page 33

Also listed in: Electric Residential Hybrid Water Heater Use & Care Manual (earlier revision), AP23657 Rev 01, page 32

Also listed in: Electric Residential Hybrid Water Heater Use & Care Manual (earlier edition), AP21681, page 27

What Rheem says to do

1. Fill storage tank with water. 2. Purge all air from the storage tank by running a hot water faucet (This is generally an installation issue and indicates there is air in the tank.) If the unit is still displaying the A008, air is still present and should be purged again. Any issues with the board or sensors would exhibit a different alarm code.

Last checked 2026-10-03.

Safety first

From the manufacturer's manual for this series.

The same code on other models

Codes mean different things on different heaters. Match the series to the model number on your rating label.

Other ProTerra / Performance Platinum hybrid (Gen V, 240V) codes