Hybrid Heater Codes

Bradford White · Heat pump RE2H (-1NCWT models)

Bradford White Heat pump RE2H (-1NCWT models) error code bAd linE (F12)

What it means

The voltage is too low at power-up. The control monitors the input line voltage 1 minute after power-up, and if the voltage is below 155V, the fault code will be displayed.

The manual says the control must detect this 1 time(s) before the code is displayed.

Source: Bradford White Heat Pump Water Heater RE2H50, RE2H65, RE2H80 mini manual / quick reference (service), 238-52395-00 (file rev A), page 3

What Bradford White says to do

These steps involve electrical testing or parts replacement. Bradford White's manuals tell owners to leave that work to a qualified service technician.

Check electrical supply line connections. Voltage should measure within +10/-15% of either 208 or 240 VAC, depending upon power supply. Badline counts stored in "F12" and can be monitored via the Control when placed in diagnostics mode. Check heating elements are not shorted to ground.

Last checked 2026-10-03.

Safety first

From the manufacturer's manual for this series.

The same code on other models

Codes mean different things on different heaters. Match the series to the model number on your rating label.