Hybrid Heater Codes

Bradford White · Heat pump RE2H (-1NCWT models)

Bradford White Heat pump RE2H (-1NCWT models) error code FL

What it means

Control checks to ensure that T3a and T3b evaporator inlet and outlet temperatures are within 2.5°F of the T5 ambient temperature 20 minutes after defrost begins.

The manual says the control must detect this 10 time(s) before the code is displayed.

Source: Bradford White Heat Pump Water Heater RE2H50, RE2H65, RE2H80 mini manual / quick reference (service), 238-52395-00 (file rev A), page 3

What Bradford White says to do

These steps involve electrical testing or parts replacement. Bradford White's manuals tell owners to leave that work to a qualified service technician.

Check airflow: fan operation, dirty filter, dirty evaporator. Check T3a, T3b, T5 sensor mounting, wiring and resistance. Check EEV wiring at control, coil placement, and operation.

Last checked 2026-10-03.

Safety first

From the manufacturer's manual for this series.

The same code on other models

Codes mean different things on different heaters. Match the series to the model number on your rating label.

Other Heat pump RE2H (-1NCWT models) codes