Bradford White · Heat pump RE2H (-1NCWT models)
Bradford White Heat pump RE2H (-1NCWT models) error code FJ
What it means
Control checks to ensure that the AC current draw is <= 20.5A while the compressor and lower heating element are both enabled. If current draw is >20.5A, the compressor will be disabled.
The manual says the control must detect this 10 time(s) before the code is displayed.
What Bradford White says to do
These steps involve electrical testing or parts replacement. Bradford White's manuals tell owners to leave that work to a qualified service technician.
Check lower heating element rated wattage. Element wattage is stamped on the heating element terminal block. Correct wattage can be found on the water heater's rating plate.
Last checked 2026-10-03.
Safety first
- DISCONNECT POWER BEFORE SERVICING. IMPORTANT: RECONNECT ALL GROUNDING DEVICES. All parts capable of conducting electrical current are grounded; grounding wires, screws, straps, clips, nuts or washers removed for service must be returned to their original condition and properly fastened. (p.1)